LingSante-Pulse: Unified Physiological Pretraining through Random-Feature Prediction and Cross-Modal Alignment
We introduce LingSante-Pulse, a physiological signal foundation model pretrained on more than 150,000 hours of physiological time series spanning diverse real-world settings. A single unified encoder processes all types of physiological sensor data, enabling flexible transfer and reuse across signal types and sensor combinations. Across 38 single-sensor, non-sleep prediction tasks spanning four domains — electroencephalography (EEG), electrocardiography (ECG), photoplethysmography (PPG), and electromyography (EMG) — plus multimodal sleep staging and single-lead sleep apnea detection, LingSante-Pulse comprehensively outperforms existing sensor-specific specialist models as well as multimodal physiological foundation models.
Domain-level and sleep-staging ranks (top) and representative downstream tasks (bottom)
Why Physiological Signals Need a Unified Model
The electrical activity of the heart, the flow of blood through peripheral vessels, the oscillations of the brain, and the rise and fall of breathing jointly reflect the physiological state of the human body.
- Electroencephalography (EEG): Scalp electrodes record the brain’s electrical activity.
- Electrocardiography (ECG): Skin electrodes record the heart’s electrical activity.
- Photoplethysmography (PPG): Optical sensors measure pulse-related changes in blood volume, often at the wrist.
- Electrooculography (EOG): Electrodes around the eyes track eye movements.
- Electromyography (EMG): Electrodes record electrical activity as muscles contract.
- Respiratory signals (RESP): Chest or abdominal belts measure breathing effort, while nasal sensors measure airflow.
LingSante-Pulse supports flexible inputs and a broad range of downstream applications
Yet real-world medical and health-monitoring scenarios are deeply fragmented. Polysomnography (PSG) simultaneously records EEG, EOG, EMG, ECG, and respiration; cardiology exams focus on the 12-lead ECG; everyday wearables typically offer only PPG or single-lead ECG. These signals observe one and the same tightly coupled physiological system from different angles — yet their modality coverage overlaps only partially.
Existing research faces a dilemma. Single-modality specialist models are constrained by the scale of a single data source, ignore the coupling between sensor signals, and transfer poorly across settings. Multimodal models capture complementarity across modalities but are usually built for a fixed scenario (e.g., a sleep model with a fixed channel configuration); when some modalities are missing, or only a single modality is available, their representations degrade sharply.
We built LingSante-Pulse to learn from whichever signals a recording contains. One encoder processes each channel independently, using a description of the signal type and lead to distinguish, for example, a wrist pulse waveform from an ECG lead. A task can use features from one channel or combine features from several without retraining the encoder.
Model Overview
Overview of LingSante-Pulse pretraining
Input channels are resampled to a uniform 128 Hz and split into non-overlapping 30-second segments. To process signals of different modalities with one encoder, natural-language text describing the “modality + lead” is converted by a frozen text encoder into conditioning vectors that accompany the raw waveform. Each physiological channel passes through the encoder independently, so the model natively supports inputs with an arbitrary number and combination of sensors.
LingSante-Pulse is pretrained with three complementary self-supervised objectives, so that the model learns both cross-modal commonality and the spectral and rhythmic structure of each individual waveform:
- Pairwise cross-modal alignment: signals recorded synchronously within the same time window are pulled together in a projection space, with a distributional regularizer preventing representational collapse.
- Structured random-feature prediction: an ever-refreshing structured random teacher network generates prediction targets, and the student learns through a linear cross-sample predictor, guaranteeing the representations remain informative.
- Masked waveform reconstruction: 50% of valid waveform segments are masked and reconstructed with a lightweight decoder, forcing the model to learn fine-grained local waveform morphology.
At inference time, the teacher, the linear head, the alignment projector, and the decoder are all discarded. Only the frozen shared encoder remains: each channel is encoded independently and fed into a lightweight task-specific readout.
Learning Shared Physiological Structure from partially overlapping modalities
In practice, datasets contain only partially paired signals. Dataset A may record EEG and ECG together, dataset B ECG and respiration, and dataset C only multi-lead ECG.
LingSante-Pulse treats the entire pretraining corpus as a sparse network graph: physiological signal types are nodes, synchronously recorded signal pairs are edges, and signals that recur across settings — ECG above all — act as hubs that connect otherwise disjoint signals.
The model encodes each physical channel independently and aligns, pairwise, the representations of signals from the same individual within the same time window. This design does not require every record to contain the full set of modalities — and it exhibits a striking transitive transfer effect: two signals that have never been directly paired (say, EEG and respiration) still benefit each other, as long as each is connected to a common hub (say, ECG).
We verified this transitivity in a controlled EEG–ECG–respiration experiment. Training saw only EEG–ECG and ECG–RESP pairs; at test time, only the respiratory signal was provided for sleep staging — a task whose human gold standard is defined primarily from EEG. Compared with controls that either excluded EEG or shuffled the EEG pairings, adding correctly aligned EEG–ECG auxiliary data raised single-channel respiratory sleep staging accuracy (Macro-F1) by a substantial 4.21 percentage points (0.399 → 0.439). This confirms that LingSante-Pulse successfully channels the advantages of joint multimodal observation across many datasets into downstream tasks performed by a single, isolated sensor.
Preserving Signal information through prediction and reconstruction
Cross-modal alignment excels at capturing global state, but it tends to neglect the morphological details private to a single signal — the shape of the QRS complex in ECG, or transient sleep spindles in EEG. This channel-private information is valuable in its own right and must survive in the representation.
We address this with structured random-feature prediction: at every training step, a freshly initialized random teacher network is generated to characterize the intrinsic structure of the input signal, and the student is trained to predict the teacher’s outputs from its own representations via a simple linear map. Because the teacher changes at every step, the encoder is constantly faced with different measurement tasks of the signal and cannot take shortcuts around any single fixed objective — it is forced to preserve the signal’s own structural features in its representation space.
Masked waveform reconstruction, meanwhile, requires the model to recover occluded segments and thereby retain fine local detail. Ablation studies show the two objectives are highly complementary: the random teacher is better at predicting amplitude, event location, and spectral properties, while reconstruction is stronger on local metrics such as pulse-to-pulse intervals.
Single-Sensor Prediction: Beating the Specialists in Four Domains
We tested the generality of the learned representations on 38 non-sleep tasks spanning PPG, ECG, EEG, and EMG — from wrist-PPG heart-rate estimation and 12-lead arrhythmia classification to 64-channel EEG motor-imagery decoding and continuous movement-trajectory decoding from 2,000 Hz EMG. The baselines include the latest specialist foundation models of each domain. All models are evaluated with a frozen encoder and only a lightweight task head trained per task, isolating the reusability of the pretrained representations themselves.
LingSante-Pulse achieves the best dataset-averaged rank in all four domains (PPG 2.32, ECG 3.08, EEG 3.00, EMG 1.33) — a single general-purpose model outperforming the dedicated experts of four domains.
- PPG: on wrist-PPG heart-rate estimation under intense motion artifacts (DaLiA), error (MAE) is 25.1% lower than the strongest specialist model; on affective and stress-state classification (WESAD), Macro-F1 improves by 9.83 percentage points over the runner-up.
- ECG: by simply concatenating the independently encoded per-lead features, the model surpasses dedicated 12-lead ECG specialists in arrhythmia classification (Macro-F1).
- EEG: the model beats the strongest specialists on both 64-channel motor imagery and 3-channel mental-arithmetic tasks (Macro-F1).
- EMG: in finger-movement trajectory decoding, despite being pretrained at 128 Hz and applied directly to 2,000 Hz EMG, LingSante-Pulse still achieves the lowest prediction error (MAE) among all models.
Average ranks of models across the four single-modality task suites
Errors on single-modality regression tasks (top) and accuracy on single-modality classification tasks (bottom)
Sleep Monitoring: From Multimodal Overnight Staging to Single-Lead Screening
Sleep staging
We evaluated automatic sleep staging — labeling every 30-second epoch of the night as Wake, REM, N1, N2, or N3 — on the public PSG datasets HMC and Sleep-EDF20.
- Strongest multimodal performance: with all channels and full-night context as input, LingSante-Pulse reaches an overnight staging Macro-F1 of 0.7859, ahead of all external multimodal sleep models.
- Single-modality inputs overtake multimodal baselines: on HMC, LingSante-Pulse using only four EEG channels already surpasses external models supplied with the full EEG + EMG + EOG + ECG + RESP suite — clear evidence of how thoroughly LingSante-Pulse mines the information in a single modality.
Sleep staging performance
Apnea screening
Sleep apnea is among the most consequential health hazards in sleep medicine. On the Apnea-ECG benchmark, we tested whether a single ECG lead can determine, minute by minute, whether the patient is experiencing an apnea event.
LingSante-Pulse achieves an AUROC of 0.918 — more than ten percentage points above dedicated ECG foundation models.
_Single-lead ECG apnea screening accuracy _
Toward a Reusable Physiological Foundation Model
LingSante-Pulse charts a new path for connecting heterogeneous physiological records: leveraging synchrony relationships to learn the intrinsic links between signals, while an ever-refreshing random teacher and masked reconstruction preserve the fine-grained structure of each signal individually. The resulting universal representation transfers seamlessly across sensor combinations and clinical settings.
We hope this approach will turn the physiological records scattered across clinical and consumer settings into a commonly exploitable research resource — helping future AI health models make better use of the rich data of the real world.
Resources
- Technical Report: LingSante-Pulse: Unified Physiological Pretraining through Random-Feature Prediction and Cross-Modal Alignment
- GitHub: inclusionAI/LingSante-Pulse
- Hugging Face: inclusionAI/LingSante-Pulse-1.0